• Scalable power on demand: With a modular architecture that supports 150kW supercharge capacity (120kW DC+22kW AC), operators can dynamically add modules based on regional traffic flow, avoiding initial redundant investments
• Multi-gun simultaneous charging: Support single/double/three-gun combination charging (DC+AC), single pile can serve up to 3 vehicles at the same time, improving the site utilization rate by more than 30%
• Maintenance cost reduced by 50% : Independent module design, only need to replace a single unit in case of failure, without machine shutdown, support hot swap technology to ensure 24 hours of operation
User value:
✅ Small cost start-up: start from the basic module, gradually expand, and reduce the threshold of initial station construction
✅ Revenue maximization: Multiple gun concurrent during peak hours, the number of single-pile daily service vehicles increased to 80 + units
✅ Worry-free operation and maintenance: module-level replacement technology, with an average time to repair < 30 minutes
• Full agreement fast charge support: compatible with CCS-2/CHAdeMO/AC Type-2 three international standards, covering Tesla, BYD, Volkswagen and other mainstream brands
• Intelligent protocol switching: Automatically identifies vehicle charging needs, dynamically allocates power, supports high voltage platforms up to 1000V (such as the Porsche Taycan)
• Future technology reservation: Support CHAOJI standard upgrades and protect operators' technology investment for 5 years
User value:
✅ Eliminate model restrictions: no need to worry about compatibility and attract more brand owners
✅ Charging efficiency improvement: the fastest 5 minutes to make up 200km, to meet the high frequency demand of online car/taxi
✅ Long-term technical support: a station, compatible with the next 5 years of new models
Nine-fold intelligent protection system:
1. Overvoltage protection (±10% automatic cut-off)
2. Lightning protection (6kV surge suppression)
3.Leakage detection (< 30mA fast response)
4. Short circuit protection (0.1sec fuse)
5. Overtemperature warning (power reduction above 55℃)
6. Reverse protection
7. Insulation monitoring (real-time leakage detection)
8. Overload protection (110% power limit)
9. Undervoltage compensation
Military grade durability:
IP54 waterproof and dust resistant to heavy rain/dust environment
IK10 impact-resistant housing to withstand unexpected collisions
-30℃~+55℃ wide temperature operation, suitable for extremely cold/high temperature areas
User value:
✅ Zero safety incidents: through DEKRA certification, the fault incidence is 60% lower than the industry average
✅ 24/7 operation: 99% availability in inclement weather
✅ Extended equipment life: metal body + forced air cooling design, the average trouble-free time > 50,000 hours
• OCPP 1.6J Full connection:
Remote monitoring: real-time view of each device status, charging records, energy consumption data
OTA Upgrade: Remotely update the program without on-site operation
Load balancing: Dynamically allocates network resources to avoid local overloads
• Multi-network redundancy design:
Support Ethernet/GPRS/LTE triple communication backup to ensure stable data transmission
4G module built-in, plug and play fast networking
• Intelligent billing system:
Support charging by power/time/mileage, flexible pricing strategy
Wechat/Alipay/Apple Pay full payment
User value:
✅ Remote operation and maintenance: save 90% of manual inspection costs
✅ Data-driven decision making: Optimize operational strategy through charging peak analysis
✅ Increase user engagement: Convenient payment + real-time bill push
• Space optimization design:
1900×725×700mm compact body, 20% less footprint than traditional pile
Bottom entry line + top exit line, suitable for underground garage/narrow road
• Multi-scenario solution:
City fast charging station: 150kW super full full taxi/online car quick recharge
Commercial complex: Dual gun design reduces queues and improves customer experience
Enterprise Park: AC+DC combination meets the needs of slow charging of commuter vehicles and fast charging of executive vehicles
User value:
✅ Prime location adaptation: Achieve efficient layout in the commercial district where the land is expensive
✅ Scenario benefit maximization: Differentiated charging mode improves device utilization
✅ Brand image enhancement: high-end industrial design to enhance the sense of science and technology
![]() | ![]() |
![]() | ![]() |
Every show is a showcase of the efforts and professionalism of the ARK team, and we have won widespread acclaim for our well-curated booths, cutting-edge technology displays and enthusiastic customer service. Whether it is in industry exchanges, product demonstrations or business negotiations, ARK has achieved remarkable results. Every interaction at the show deepens relationships with partners and attracts the interest of new customers. |
France | ![]() |
Romania | ![]() |
SYSTEM | |
Charging type | Mode 4 |
Dimension (H x W x D) | 1900 x 700 x 700mm |
Enclosure protection grade | IP54, IK10 |
Cable routing | Bottom inlet, top outlet wiring |
Net weight | 310kgs |
Numbers of plugs | 3 |
Charging standard | IEC 61851-1, IEC 61851-23 |
Certificate | CE, EN 61851-23:2014 + EN 61851-23:2014/AC:2016-06, IEC 61851-21-2: 2018, EN IEC 61851-21-2: 2021 |
Protection | Over/under voltage protection, overload protection, current leakage protection, grounding protection, lightening surge protection |
Accessories | Cable management balancer reel |
Input | |
Input voltage | 400Vac +/-10%, 50/60Hz, 3-phase + neutral + PE |
Input current | 0 - 102A |
Power factor | 0.99 at nominal output |
Efficiency | 94% at nominal output |
DC Output | |
Outlet connectors | DC: CCS-2 |
DC output power (single charging) | CCS: 60kW max |
DC output power (simultaneous charging) | CCS: 30kW of each plug |
DC output voltage range | 200 – 1000VDC |
DC Output current range | CCS: 0 – 200A |
User interface | |
User authentication | RFID, QR code, Mobile App |
Display | 7" LCD touch screen |
Support languages | English, Spanish, Polish (other languages upon request) |
Network interface | Ethernet and LTE |
Protocol | OCPP 1.6J, future upgradable to 2.0 |
Environmental | |
Working temperature | -30°C – +55°C, derating from 55°C to 75°C |
Working humidity | 5% – 95% non-condensation |
Altitude | <2000m |
Cooling | Fan cooling |