Availability: | |
---|---|
Quantity: | |
When integrated with the off-grid continuous Industrial Power Conditioning System, off-grid Power Conditioning System, Industrial off-grid Power Conditioning System, continuous off-grid Power Conditioning System, Industrial Power Conditioning System, and continuous Industrial Power Conditioning System, the AK-PCS1 series PCS provides a holistic solution to address a wide range of power conditioning requirements.
Capacity
50kW power module based modular design achives 50-150kW PCS system
Working Mode
Grid-connected mode and off-grid mode, also known as microgrid mode.
Multi-fuctional system
The multi-functional system enables seamless transfer between on-grid and off-grid operations, facilitates the connection of multiple battery strings, and allows integration with PV ESS (Photovoltaic Energy Storage System).
Optional STS
Optional STS module support to achive on grid/ off grid seamless transfer
Designing power conversion systems (PCS) typically necessitates:
Precise measurement of voltage, current, and temperature.
Implementation of modular, fail-safe power stage configurations.
Achieving high efficiency and power density.
Continuous real-time monitoring for fault detection and correction.
Model type | AK-PCS1-50K | AK-PCS1-100K | AK-PCS1-150K | ||
Utility-interactive Mode | |||||
Battery Voltage Range | 600 – 900 V | ||||
Max. DC Current | 110 A | 220 A | 330 A | ||
Max. DC Power | 55 kW | 110 kW | 165 kW | ||
AC Voltage | 400 V +/- 15% | ||||
AC Current | 72 A | 144 A | 216 A | ||
Nominal AC Output Power | 50 kW | 100 kW | 150 kW | ||
AC Frequency | 50 Hz / 60 Hz +/-2.5 Hz | ||||
Output THDi | ≤ 3% | ||||
AC PF | -1 to 1 | ||||
Stand-alone Mode | |||||
Battery Voltage Range | 600 – 900 V | ||||
Max. DC Current | 110 A | 220 A | 330 A | ||
AC Output Voltage | 400 V +/- 10% | ||||
AC Output Current | 72 A (Max. 79 A) | 144 A (Max. 158 A) | 216 A (Max. 237 A) | ||
Nominal AC Output Power | 50 kW | 100 kW | 150 kW | ||
Max. AC Power | 55 kW | 110 kW | 165 kw | ||
Output THDu | ≤ 3% (Linear load) | ||||
AC Frequency | 50 Hz / 60 Hz | ||||
Overload Capability | 110%: 10 min 120%: 1 min | ||||
Physical | |||||
Peak Efficiency | ≥ 97% | ||||
Cooling | Forced Air Cooling | ||||
Noise | ≤ 70 dB | ||||
Enclosure | IP20 (IP54 optional with outdoor cabinet) | ||||
Max. Elevation | 3000 m (> 2000 m derating) | ||||
Operation Ambient Temperature | -20°C – +50°C, derating over 45°C | ||||
Humidity | 5% – 95% non-condensation | ||||
Dimension (H x W x D) | 2100 mm X 800 mm x 1000 mm | ||||
Weight | 700 KGS | 1000 KGS | 1100 KGS | ||
Installation | Vertical Installation | ||||
Other | |||||
Isolation | Built-in Transformer | ||||
Protection | OTP, AC OVP / UVP, OFP / UFP, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding | ||||
AC Connection | Grid connected: 3-phase + PE Off-grid: 3-phase + N + PE | ||||
Display | 10.1” Touch Screen | ||||
Support languages | English (other languages upon request) | ||||
Communication | RS 485, CAN, Ethernet |