The Static Var Generator (SVG) operates by connecting a voltage-type inverter to the power grid in parallel through a filter, allowing for the adjustment of the AC output voltage's amplitude and phase. It dynamically and accurately compensates for reactive power in the power grid system, with an instantaneous response time of less than 50 microseconds and a full response time of less than 10 milliseconds, effectively preventing overcompensation and undercompensation. Currently, SVG stands out as the optimal solution in the field of reactive power compensation.
The principle of the SVG is very similar to that of Active Power Filter, When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. SVG is also capable of correcting load imbalance.
-10℃~40℃ full power continuous operation, 40℃~50℃ capacity reduction does not exceed 40%
Reactive power compensation, harmonic compensation, three-phase unbalance treatment
Neutral zero sequence current filtering capability is three times that of phase line (high equipment model)
It can directly continuously and accurately compensate the power factor of the high-voltage 10kV/35kV incoming line side (the average power factor value after compensation is greater than 92%), and can still have the power factor compensation function when the current sampling point is in the high-voltage 10kV/35kV side.
Reactive power compensation < 10ms, harmonic compensation < 20ms
Reactive power compensation rate is greater than 98%; 2~51 times, the comprehensive compensation rate of 25 channel harmonic is ≥95%
The core components are guaranteed by brand
Residential power distribution system, drainage and sewage treatment industry, distributed photovoltaic industry, chemical industry, chemical fiber and petroleum industry, foundry and cement industry, coal and mining industry, automobile manufacturing industry, etc.
TYPE | Series 220V | Series 400V | Series 500V | Series 690V |
Max neutral w ire current | 5KVar | 10KVar15KVar/ 35KVar/50KVar/ 75KVar/100KVar | 90KVar | 120KVar |
Nominal voltage | AC220V(-20%~+20%) | AC380V(-20%~+20%) | AC500V(-20%~+20%) | AC690V(-20%~+20%) |
Rated frequency | 50Hz±5% | |||
Network | Single phase | Three-phase three-wire/three-phase four-wire | ||
Response time | <10ms | |||
Reactive power compensation rate | >95% | |||
Machine efficiency | >97% | |||
Switching frequency | 32kHz | 16kHz | 12.8kHz | 12.8kHz |
Feature selection | Deal with harmonics/Deal with harmonics and reactive power | Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options | ||
Numbers in parallel | No limitation. A single centralized monitoring module can be equipped with up to 8 power modules | |||
Communication methods | Two-channel RS485 communication interface (support GPRS/WIFIwireless communication) | |||
Altitude w ithout derating | <2000m | |||
Temperature | -20~+50°C | |||
Humidity | <90% RH | |||
Pollution level | Below level Ⅲ | |||
Protection function | Overload protection, hardware over-current protection, over-voltage protection, power grid voltage imbalance protection, power | |||
Noise | <50dB | <60dB | <65dB | |
Installation | Rack/wall hanging | Rack | ||
Into the way of line | Back entry (rack type), top entry (wall-mounted) | Top entry | ||
Protection grade | IP20 |