• Full harmonic compensation: real-time detection and compensation of 2-50 harmonics, response time < 40ms, to protect inverter, PLC and other precision equipment from voltage fluctuations damage
• Dynamic reactive power compensation: the power factor is increased to 0.99, reducing the reactive power loss of the grid and avoiding the penalty of the power supply bureau
• Three-phase unbalance adjustment: automatically balance the three-phase current, reduce the risk of neutral line overload, and ensure the stable operation of multi-phase equipment
User value:
✅ Prolong equipment life by 30%+ : reduce motor heating and insulation aging caused by harmonic interference
✅ Production continuity guarantee: avoid line downtime or data loss due to voltage fluctuations
✅ Electricity cost reduction: power factor standards, reduce reactive power penalty, annual savings of up to 15%-20%
• Modular expansion: Support 8 power modules in parallel, compensation capacity from 23A to 400A flexible configuration, to meet the needs of plant expansion or load increase
• Intelligent diagnosis system: real-time monitoring of equipment status, automatic warning of faults (such as overtemperature, overload), support for remote OTA upgrade
• Multi-protocol compatibility: Supports RS485/Modbus, Wi-Fi, 4G and other communication modes, and seamlessly connects to the smart grid management platform
User value:
✅ Investment protection: on-demand configuration in the early stage, smooth expansion in the later stage, reducing upgrade costs
✅ Operation and maintenance cost is reduced by 50% : remote monitoring reduces manual inspection, and fault location is accurate to the module
✅ Data-driven optimization: Optimize your power consumption strategy through cloud data analysis
• Wide temperature operation: -20℃~+50℃ working temperature, suitable for extreme environment such as cold storage and boiler room
• IP20 protection + seismic design: resist dust and vibration, suitable for complex scenes such as factory workshops and rail transit
• Low noise operation: < 55dB, to meet the needs of noise sensitive places such as hospitals and data centers
User value:
✅ all-weather stable operation: 99% availability in high temperature, high humidity and dusty environment
✅ Full coverage of scenarios: from factories to commercial buildings, from new energy generation to charging pile groups can be adapted
✅ Green: in line with RoHS standards, standby power consumption < 1%
scene | core value |
manufacturing industry | Protect frequency converters and CNC machine tools, reduce equipment failure rates, and increase the yield of qualified products. |
DC | Eliminate harmonic pollution from IT devices, ensure stable server operation, and extend UPS service life |
commercial complex | Balance three-phase loads to avoid flickering of the lighting system and enhance customer experience. |
New energy power generation | Compensate for the harmonics of photovoltaic/wind power inverter to meet the grid connection standards. |
transportation junction | Mitigate harmonic pollution in charging pile clusters and ensure the safety of the power supply system for rail transit. |
User value:
✅ Industry customization: Provide wall-mounted, rack-mounted, cabinet installation methods, suitable for different site conditions
✅ Compliance guarantee: through CE certification, in line with IEC 61000-3-2 and other international standards, to ensure the acceptance of power
☆☆☆☆☆ As a data center manager, harmonic distortion was killing our UPS batteries. The AHF system not only stabilized our power but also cut maintenance costs by half. The modular design made expanding capacity a breeze—highly recommend! |
☆☆☆☆☆ Finally, a filter that’s easy to install AND maintain! The plug-and-play modules saved us hours during upgrades. Even our old machinery runs better now—no more strange buzzing sounds. 10/10! |
Q1: How does AHF solve harmonic problems?
A1: AHF can offset harmonic pollution in the power grid by monitoring the load current in real time and generating compensation current with the same amplitude and reverse phase of harmonics. The response speed is less than 40ms and can compensate 2-50 harmonics.
Q2: What about three-phase unbalance?
A2: AHF can automatically adjust the three-phase current balance, eliminate the risk of neutral line overload, and ensure the stable operation of multi-phase equipment, especially suitable for non-linear loads such as charging piles and motor groups.
Q3: Is the maintenance cost high?
A3: Modular design supports hot swap, faulty modules are replaced within 5 minutes, and the annual maintenance cost is 50% lower than that of traditional filters. Support remote monitoring, early warning of potential problems.
Q4: What international standards are met?
A4: Passed the CE certification, in line with IEC 61000-3-2, EN 61800-3 and other harmonic governance standards, to ensure the acceptance of the power company.
Q5: Can it adapt to different voltage levels?
A5: Supports 220V, 400V, 500V, 690V and other voltage levels, providing customized solutions to meet special requirements.